DNK (Xiamen) Electrical Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Yu Judy
  • Company Name : DNK (Xiamen) Electrical Co., Ltd.
  • Tel : 86-592-2068080
  • Fax : 86-592-2038080
  • Address : Fujian,Xiamen,No. 26, Xiangming Road, (Xiang'an) Ind Park, Torch Hi-Tech Industry Development Zone
  • Country/Region : China
  • Zip : 361101

High Voltage Outdoor 12kV Falling Fuses Cutout - DNK

High Voltage Outdoor 12kV Falling Fuses Cutout - DNK
Product Detailed
Related Categories:Fuses
DNK have the most innovative technology in the international. We will provide the excellent service and good price for you. DESCRIPTION

  SSOC (NCF) outdoor AC high voltage falling fuse series are the devices for overcurrent protection. The fuse installed on the distribution transformer or pole of power line serves as device for overload protection and switching on/off the load current. The fuse is composed of a main insulating and conducting structure and an arcing tube. The stationary contacts are fixed at both ends of the insulating post and the moving contacts at both ends of the fuse tube composed of an arcing glass tube outside. Equipped with an arcing chamber and elastic auxiliary contacts to interrupt load current and capacitor current the SSOC (NCF)3 fuse is able to switch on/off the load current.

HIGH QUALITY MATERIALFuse tube - epoxy fiber glass with fiber lining coated with special ultraviolet resistant material, the corresponding disconnect switch knife can be here selected.

      2.    Upper contact - silver to silver, high contact pressure squeezed by stainless steel spring.

             

    3.     Trunnion - high strength cast copper, silver - plated, and pressed on the side surface of the hinge around the trunnion surface to ensure the fuse tube alignment while switching-on.

             

            

SAFE PACKAGE

  

OUTLINE DRAWINGINSTALLATION DRAWING TECHNICAL PARAMETER: SANDRAD:

    The design and test of SSOC (NCF) fuse accords with requirments of the following standards:

IEC282.1                                     IEC787ANSI C37.41-94                        ANSI C37.42-94GB 15166.3-2008                     GB311.1-97DL/T 640-97                               DL/T 593-96

High Voltage Outdoor 12kV Falling Fuses Cutout - DNK



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.